ERRATA
SHEET
After
this
manual
was
printed,
refinements
In
equipment
design
occurred.
This
sheet
lists
exceptions
to
data
appearing
later
in
this
manual.
AMENDMENT
TO
SECTION
2-
INSTALLATION
Add
Section
2-3.
650/1000
An~ere
Model
Selector
Switch
WARNING:
ELECTRIC
SHOCK
can
kill.
Do
not
touch
live
electrical
parts.
Shut
down
welding
power
source
and
disconnect
the
Remote
Pendant
Cont
rol
before
changing
posi
tion
of
dip
switches.
ELECTROSTATIC
DISCHARGE
(ESD)
can
damage
circuit
board
components.
Put
on
properly
grounded
wrist
strap
BEFORE
handling
circuit
boards.
Transport
all
static-sensitive
components
in
proper
static-shielding
carriers
or
packages.
Perform
work
only
at
a
static-safe
work
area.
This
Remote
Pendant
Control
is
designed
to
be
used
with
either
a
650
or
1000
ampere
intellipuise
welding
power
source.
A
dip
switch
is
located
on
circuit
board
PC5
to
set
up
the
Remote
Pendant
Control
for
operation
with
650
or
1000
ampere
models.
The
unit
is
shipped
from
the
factory
set
up
for
operation
with
the
650
ampere
models.
Proceed
as
follows
to
set
up
the
Remote
Pendant
Control
for
operation
with
1000
ampere
models:
1.
Remove
cover.
2.
Place
both
dip
switches
in
the
down
position
for
operation
with
1000
ampere
models.
Place
both
dip
switches
in
up
position
for
operation
with
650
ampere
models
(see
Figure
2-2
on
this
Errata
Sheet).
3.
Reinstall
cover.
Add
Figure
2-2.
Dip
Switch
Positions
And
Locations
a
/~
Front
Panel
>
Both
dip
switches
down
for
1000
amp.r.
model
operation
Both
dip
switches
up
for
050
amp.r.
model
operation
8.113
509
FIgure
2-2.
Dip
Switch
Positions
And
Locations