3
XR-Control
Genuine Miller
Options
*Factory option available only in XR-Control packages
— see Ordering Information on page 4.
Voltage Control*
#194 027 Field
Allows voltage
adjustment at the
current XR-Control
when used with Miller
electrically controlled,
constant-voltage DC power sources that
have a 14-pin receptacle.
Dual Schedule
Control*
#193 276 Field
Allows two different
welding conditions
(voltage and wire
feed speed) to be
used on the same
wire. This is ideal
when different heat settings are required or
when the need arises to change conditions
while welding, i.e. different material
thickness, out of position welding, etc. Is
also ideal for use as a start control or crater
fill control.
Note: The Digital Display is required to use the Dual
Schedule. Only for use with Miller CV or CC/CV power
sources. Dual Schedule Switch required.
Digital Display
V/WFS
#193 274 Field
For XR Control prior
to serial #LC122752.
Note: Voltage Sense Lead (#209 867) required for
voltage display when used with non-solid-state Miller
and competitive power sources.
Allows wire feed speed to be preset and
displayed. Will also monitor voltage while
welding. If used with current manufactured
Miller CV or CC/CV power sources
(excluding CPs) and the optional voltage
control or dual schedule control is used,
the arc voltage can also be preset on the
digital display. Includes back-lit LCD digital
display that is easy to read in virtually any
lighting condition. A selector switch allows
the display to switch between wire feed
speed and voltage.
Dual Schedule Switches
DSS-30 #193 271 Field
For 15 ft (4.6 m) and 30 ft (9 m) guns
Required to operate the dual schedule
control. A two position slide switch that can
be positioned at the push-pull gun to
remotely select schedule A or B conditions.
Gas Flowmeter*
#193 278 Field
#197 793 Field w/CE
Monitors and adjust gas flow
at the XR Control.
Note: Gas pressure must be
controlled at the primary gas supply
with the use of a regulator.
Spot Weld/Burnback
Control #193 279 Field
Provides up to 5 seconds
of spot weld time and
0 (zero) to 0.25 seconds
of burnback time.
XR-Control
Genuine Miller
Accessories
Optima
™
MIG (GMAW)
Pulse Control #043 389
For XMT 304, 350, 456
CC/CV and Invision 304P,
456 P and Phoenix 456
CC/CV. A multipurpose,
microproces sor-based
pulse control for synergic
MIG (wire welding or
GMAW), manual MIG pulsing or standard
MIG welding. Use this control with all
above power sources and any Miller wire
feeder. Includes 25 ft (7.6 m) cord with 14-
pin plug.
PSA-2 Control #141 604
Required when using the
XR Control with power
sources having only
115 VAC available.
Mounts at power source
and includes a 10 ft (3 m)
115 VAC cord and
contactor cord with Hubbell connectors.
A simple modification in the PSA-2 control
also allows it to be used with competitive
constant voltage power sources requiring
a contact closure for contactor control.
The PSA-2 includes a 14-pin receptacle
for direct connection of the standard
interconnecting cord and optional extension
cords. Bracket included for side mounting
to the power source.
Note: When using the PSA-2 control, the optional
Remote Voltage Control is not functional.
Extension Cords
#122 973 25 ft (7.6 m)
#122 974 50 ft (15.2 m)
#122 975 75 ft (22.9 m)
Provides 14-pin, 24 VAC, contactor and
voltage control. Can be added to the
standard 10 ft (3 m) feeder cord to extend
feeder farther from power source.
Water Coolant Systems
Coolmate
™
3 #043 007 115 VAC
Coolmate
™
3 #043 008 230 VAC
Coolmate
™
V3 #043 009 115 VAC
Coolmate
™
4 #042 288 115 VAC
For use with water-cooled guns. Refer to
Lit. Index No. AY/7.2 for additional coolant
system information.
Coolant #043 809
Sold in cases of four 1-gallon recyclable
plastic bottles.
Coolmate V3
Coolmate 4
Coolmate 3
Komentarze do niniejszej Instrukcji